The setup consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of is measured with the help of measuring tank and stop watch.
➢To determine the losses due to fiction in pipes.
➢To determine the friction factor for Darcy-Weisbach equation
➢Electricity supply: Single Phase, 220 V AC, 50 Hz, 5-15 amp combined socket with earth
➢ connection. Earth voltage should be less than 5 volts.
➢Water Supply: Initial fill
➢ Floor Drain.
➢Floor Area 1.5 x 0.75 m.
➢Pipe Test Section : (i) Dia ½”, Length: 1m, Material G.I. (ii) Dia ¾”, Length: 1m, Material G.I.
➢Water Circulation : ½ HP Pump, Crompton make.
➢Flow Measurement : Using Measuring Tank with Piezometer, Capacity 25 Ltrs.
➢Sump Tank : Capacity 50 Ltrs.
➢Stop Watch : Electronic.
➢Control Panel Comprises of : Standard make On/Off Switch, Mains Indicator, etc
➢Tanks will be made of Stainless Steel.
➢An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
➢The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint.