The set up consists of a ½” bend and elbow, a sudden expansion & sudden Contraction fitting from 15mm to 25mm, ball valve and gate valve. Pressure tapings are provided at inlet and outlet of these fittings under test. A differential manometer fitted in the line gives pressure loss of individual fittings. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
➢ To determine loss of head in the fittings at various water flow rates.
➢ To measure the loss coefficient for the pipe fittings.
➢Electricity supply: Single Phase, 220 V AC, 50 Hz, 5-15 amp combined socket with earth connection. Earth voltage should be less than 5 volts.
➢ Water Supply (Initial Fill)
➢Floor Drain.
➢Floor Area: 1.5 m x 0.75 m.
➢ Sudden Enlargement : From 15mm to 25mm
➢ Sudden Contraction : From 25mm to 15mm.
➢ Bend : ½”
➢ Elbow : ½”
➢ Ball valve : ½”
➢ Gate valve : ½”
➢ Water Circulation : ½ HP Pump, Crompton make.
➢ Flow Measurement : Using Measuring Tank with Piezometer, Capacity 25 Ltrs.
➢ Pressure Drop Measurement: Differential water manometer
➢ Sump Tank : Capacity 50 Ltrs.
➢ Stop Watch : Electronic.
➢ Control Panel Comprises of : Standard make On/Off Switch, Mains Indicator,etc.
➢ Tanks will be made of Stainless Steel.
➢ An ENGLISH instruction manual consisting of experimental procedures, block diagram etc. will be provided along with the Apparatus
➢ The whole set-up is well designed and arranged on a rigid structure painted with industrial PU Paint